Through bolt anchor for heavy loads in uncracked concrete. Opt.7 ETA Assessed. A2 Stainless steel shaft. A2 Stainless steel clip
ASSESSMENTS AND CERTIFICATES
ETA UN 05-0242
Fire restistant
CE 2005
Size
THICKNESS MAX.FIXTURE [mm]
MIN. SUBSTRATE THICKNESS
AXIS LETTER
(LENGTH)
Min. Order Qty.
Pcs. Box
Pcs. Masterbox
Technical Info.
M6 x 45 Ø6
1
100
A
0
200
1.200
tfix - Max. fixture thickness1
SW - Installation key10
df - Ø Element to fix7
Tins - Torque (Nm)7
hef - Effective depth25
hnom - Min. anchor depth35
h1 - Drill hole depth min.40
d0 - Ø Drill6
hmin - Min. substrate thickness100
L - Lenght45
M6 x 60 Ø6
2
100
B
0
200
1.200
tfix - Max. fixture thickness2
SW - Installation key10
df - Ø Element to fix7
Tins - Torque (Nm)7
hef - Effective depth40
hnom - Min. anchor depth50
h1 - Drill hole depth min.55
d0 - Ø Drill6
hmin - Min. substrate thickness100
L - Lenght60
M6 x 80 Ø6
22
100
D
0
200
1.200
tfix - Max. fixture thickness22
SW - Installation key10
df - Ø Element to fix7
Tins - Torque (Nm)7
hef - Effective depth40
hnom - Min. anchor depth50
h1 - Drill hole depth min.55
d0 - Ø Drill6
hmin - Min. substrate thickness100
L - Lenght80
M6 x 120 Ø6
62
100
G
0
100
600
tfix - Max. fixture thickness62
SW - Installation key10
df - Ø Element to fix7
Tins - Torque (Nm)7
hef - Effective depth40
hnom - Min. anchor depth50
h1 - Drill hole depth min.55
d0 - Ø Drill6
hmin - Min. substrate thickness100
L - Lenght120
M6 x 140 Ø6
82
100
I
0
100
600
tfix - Max. fixture thickness82
SW - Installation key10
df - Ø Element to fix7
Tins - Torque (Nm)7
hef - Effective depth40
hnom - Min. anchor depth50
h1 - Drill hole depth min.55
d0 - Ø Drill6
hmin - Min. substrate thickness100
L - Lenght140
M6 x 160 Ø6
102
100
J
0
100
400
tfix - Max. fixture thickness102
SW - Installation key10
df - Ø Element to fix7
Tins - Torque (Nm)7
hef - Effective depth40
hnom - Min. anchor depth50
h1 - Drill hole depth min.55
d0 - Ø Drill6
hmin - Min. substrate thickness100
L - Lenght160
M6 x 170 Ø6
112
100
K
0
100
400
tfix - Max. fixture thickness112
SW - Installation key10
df - Ø Element to fix7
Tins - Torque (Nm)7
hef - Effective depth40
hnom - Min. anchor depth50
h1 - Drill hole depth min.55
d0 - Ø Drill6
hmin - Min. substrate thickness100
L - Lenght170
M6 x 180 Ø6
122
100
L
0
100
300
tfix - Max. fixture thickness122
SW - Installation key10
df - Ø Element to fix7
Tins - Torque (Nm)7
hef - Effective depth40
hnom - Min. anchor depth50
h1 - Drill hole depth min.55
d0 - Ø Drill6
hmin - Min. substrate thickness100
L - Lenght180
M8 x 50 Ø8
4
100
A
0
100
800
tfix - Max. fixture thickness4
SW - Installation key13
df - Ø Element to fix9
Tins - Torque (Nm)20
hef - Effective depth23
hnom - Min. anchor depth35
h1 - Drill hole depth min.40
d0 - Ø Drill8
hmin - Min. substrate thickness100
L - Lenght50
M8 x 75 Ø8
5
100
C
0
100
600
tfix - Max. fixture thickness5
SW - Installation key13
df - Ø Element to fix9
Tins - Torque (Nm)20
hef - Effective depth48
hnom - Min. anchor depth60
h1 - Drill hole depth min.65
d0 - Ø Drill8
hmin - Min. substrate thickness100
L - Lenght75
M8 x 90 Ø8
20
100
E
0
100
600
tfix - Max. fixture thickness20
SW - Installation key13
df - Ø Element to fix9
Tins - Torque (Nm)20
hef - Effective depth48
hnom - Min. anchor depth60
h1 - Drill hole depth min.65
d0 - Ø Drill8
hmin - Min. substrate thickness100
L - Lenght90
M8 x 115 Ø8
45
100
G
0
100
400
tfix - Max. fixture thickness45
SW - Installation key13
df - Ø Element to fix9
Tins - Torque (Nm)20
hef - Effective depth48
hnom - Min. anchor depth60
h1 - Drill hole depth min.65
d0 - Ø Drill8
hmin - Min. substrate thickness100
L - Lenght115
M10 x 70 Ø10
3
100
C
0
100
400
tfix - Max. fixture thickness3
SW - Installation key17
df - Ø Element to fix12
Tins - Torque (Nm)35
hef - Effective depth42
hnom - Min. anchor depth54
h1 - Drill hole depth min.60
d0 - Ø Drill10
hmin - Min. substrate thickness100
L - Lenght70
M10 x 90 Ø10
10
110
E
0
100
400
tfix - Max. fixture thickness10
SW - Installation key17
df - Ø Element to fix12
Tins - Torque (Nm)35
hef - Effective depth55
hnom - Min. anchor depth67
h1 - Drill hole depth min.75
d0 - Ø Drill10
hmin - Min. substrate thickness110
L - Lenght90
M10 x 120 Ø10
40
110
G
0
50
300
tfix - Max. fixture thickness40
SW - Installation key17
df - Ø Element to fix12
Tins - Torque (Nm)35
hef - Effective depth55
hnom - Min. anchor depth67
h1 - Drill hole depth min.75
d0 - Ø Drill10
hmin - Min. substrate thickness110
L - Lenght120
M10 x 150 Ø10
70
110
I
0
50
200
tfix - Max. fixture thickness70
SW - Installation key17
df - Ø Element to fix12
Tins - Torque (Nm)35
hef - Effective depth55
hnom - Min. anchor depth67
h1 - Drill hole depth min.75
d0 - Ø Drill10
hmin - Min. substrate thickness110
L - Lenght150
M12 x 75 Ø12
5
100
C
0
50
300
tfix - Max. fixture thickness5
SW - Installation key19
df - Ø Element to fix14
Tins - Torque (Nm)60
hef - Effective depth43
hnom - Min. anchor depth55
h1 - Drill hole depth min.60
d0 - Ø Drill12
hmin - Min. substrate thickness100
L - Lenght75
M12 x 90 Ø12
13
120
D
0
50
200
tfix - Max. fixture thickness13
SW - Installation key19
df - Ø Element to fix14
Tins - Torque (Nm)60
hef - Effective depth50
hnom - Min. anchor depth62
h1 - Drill hole depth min.70
d0 - Ø Drill12
hmin - Min. substrate thickness120
L - Lenght90
M12 x 110 Ø12
18
130
F
0
50
200
tfix - Max. fixture thickness18
SW - Installation key19
df - Ø Element to fix14
Tins - Torque (Nm)60
hef - Effective depth65
hnom - Min. anchor depth77
h1 - Drill hole depth min.85
d0 - Ø Drill12
hmin - Min. substrate thickness130
L - Lenght110
M12 x 140 Ø12
48
130
I
0
50
200
tfix - Max. fixture thickness48
SW - Installation key19
df - Ø Element to fix14
Tins - Torque (Nm)60
hef - Effective depth65
hnom - Min. anchor depth77
h1 - Drill hole depth min.85
d0 - Ø Drill12
hmin - Min. substrate thickness130
L - Lenght140
M16 x 90 Ø16
4
100
D
0
25
150
tfix - Max. fixture thickness4
SW - Installation key24
df - Ø Element to fix18
Tins - Torque (Nm)120
hef - Effective depth49
hnom - Min. anchor depth69
h1 - Drill hole depth min.75
d0 - Ø Drill16
hmin - Min. substrate thickness100
L - Lenght90
M16 x 145 Ø16
23
168
I
0
25
100
tfix - Max. fixture thickness23
SW - Installation key24
df - Ø Element to fix18
Tins - Torque (Nm)120
hef - Effective depth84
hnom - Min. anchor depth104
h1 - Drill hole depth min.110
d0 - Ø Drill16
hmin - Min. substrate thickness168
L - Lenght145
M16 x 170 Ø16
48
168
K
0
25
75
tfix - Max. fixture thickness48
SW - Installation key24
df - Ø Element to fix18
Tins - Torque (Nm)120
hef - Effective depth84
hnom - Min. anchor depth104
h1 - Drill hole depth min.110
d0 - Ø Drill16
hmin - Min. substrate thickness168
L - Lenght170
M20 x 120 Ø20
5
145
G
0
20
40
tfix - Max. fixture thickness5
SW - Installation key30
df - Ø Element to fix22
Tins - Torque (Nm)240
hef - Effective depth71
hnom - Min. anchor depth93
h1 - Drill hole depth min.105
d0 - Ø Drill20
hmin - Min. substrate thickness145
L - Lenght120
M20 x 170 Ø20
23
206
K
0
20
40
tfix - Max. fixture thickness23
SW - Installation key30
df - Ø Element to fix22
Tins - Torque (Nm)240
hef - Effective depth103
hnom - Min. anchor depth125
h1 - Drill hole depth min.135
d0 - Ø Drill20
hmin - Min. substrate thickness206
L - Lenght170
M20 x 220 Ø20
73
206
O
0
20
40
tfix - Max. fixture thickness73
SW - Installation key30
df - Ø Element to fix22
Tins - Torque (Nm)240
hef - Effective depth103
hnom - Min. anchor depth125
h1 - Drill hole depth min.135
d0 - Ø Drill20
hmin - Min. substrate thickness206
L - Lenght220
【FRICTION-BASED OPERATION】 Torque-controlled wedge-type metal expansion anchor (friction-based operation) with external thread. Withstands heavy loads thanks to its friction-based operation.
【VERSATILITY】 Suitable for a wide variety of anchoring applications, such as structural fixings in non-cracked concrete, safety barriers, fixing of signs, machinery, boilers, road signs, billboards or fixing of timber structures to concrete.
【APPLICATIONS】 Recommended for high-load installations. Recommended for installation in non-cracked concrete and/or reinforced concrete. (Non-cracked concrete of grades C20/25 to C50/60). Suitable for two installation depths and for static or quasi-static loads.
【HIGH-QUALITY MANUFACTURE】 Manufactured from A4 stainless steel. Available in a galvanised steel version and in A2 grade stainless steel.
【VARIOUS SIZES】 A range of lengths and diameters, from M6 x 45 Ø6 mm to M20 x 220 Ø20 mm.
Nuestro departamento de ingeniería pone a tu disposición formaciones específicas y personalizadas en los diferentes temas relacionados con el mundo de la fijación: fijaciones metálicas o químicas, sistemas de instalación, normativas, realización de cálculos…
visitas a obra
La relación con nuestros clientes no finaliza con la venta de nuestros productos. Desde INDEX® entendemos que en muchas ocasiones es necesario un acompañamiento en obra donde nuestra experiencia es la mejor aliada para que todo encaje a la perfección. Nuestros ingenieros y técnicos apoyarán a los responsables de cada proyecto en la planificación y selección de la mejor solución con el fin de ahorrar tiempo y costes de la manera más efectiva.
SERVICIOS DE INGENIERÍA Y REALIZACIÓN DE CÁLCULOS
Desde INDEX® queremos ofrecer el servicio más integral a nuestros clientes. Además de proporcionarles las mejores soluciones en fijaciones y anclajes, nuestro equipo de ingenieros especializados, asesora técnicamente a todos nuestros clientes. Además, disponemos de potentes herramientas de software para realizar los cálculos necesarios con total exactitud.