Through bolt anchor for heavy loads in cracked & uncracked concrete. Opt.1 ETA Assessed. Zinc-plated shaft. Stainless steel clip
ASSESSMENTS AND CERTIFICATES
ETA CU 12-0397
Fire restistant
SEISMIC C1
SEISMIC C1&C2
CE 2012
VDS
Size
THICKNESS MAX.FIXTURE [mm]
MIN. SUBSTRATE THICKNESS
AXIS LETTER
(LENGTH)
Min. Order Qty.
Pcs. Box
Pcs. Masterbox
Technical Info.
M8 x 50 Ø8
2
100
A
0
100
800
tfix - Max. fixture thickness2
SW - Installation key13
df - Ø Element to fix9
Tins - Torque (Nm)20
hef - Effective depth30
hnom - Min. anchor depth37
h1 - Drill hole depth min.40
d0 - Ø Drill8
hmin - Min. substrate thickness100
L - Lenght50
M8 x 75 Ø8
9
100
C
0
100
600
tfix - Max. fixture thickness9
SW - Installation key13
df - Ø Element to fix9
Tins - Torque (Nm)20
hef - Effective depth48
hnom - Min. anchor depth55
h1 - Drill hole depth min.60
d0 - Ø Drill8
hmin - Min. substrate thickness100
L - Lenght75
M8 x 95 Ø8
29
100
E
0
100
600
tfix - Max. fixture thickness29
SW - Installation key13
df - Ø Element to fix9
Tins - Torque (Nm)20
hef - Effective depth48
hnom - Min. anchor depth55
h1 - Drill hole depth min.60
d0 - Ø Drill8
hmin - Min. substrate thickness100
L - Lenght95
M8 x 115 Ø8
49
100
G
0
100
400
tfix - Max. fixture thickness49
SW - Installation key13
df - Ø Element to fix9
Tins - Torque (Nm)20
hef - Effective depth48
hnom - Min. anchor depth55
h1 - Drill hole depth min.60
d0 - Ø Drill8
hmin - Min. substrate thickness100
L - Lenght115
M10 x 90 Ø10
10
120
E
0
100
400
tfix - Max. fixture thickness10
SW - Installation key17
df - Ø Element to fix12
Tins - Torque (Nm)40
hef - Effective depth60
hnom - Min. anchor depth68
h1 - Drill hole depth min.75
d0 - Ø Drill10
hmin - Min. substrate thickness120
L - Lenght90
M10 x 105 Ø10
25
120
F
0
50
300
tfix - Max. fixture thickness25
SW - Installation key17
df - Ø Element to fix12
Tins - Torque (Nm)40
hef - Effective depth60
hnom - Min. anchor depth68
h1 - Drill hole depth min.75
d0 - Ø Drill10
hmin - Min. substrate thickness120
L - Lenght105
M10 x 115 Ø10
35
120
G
0
50
200
tfix - Max. fixture thickness35
SW - Installation key17
df - Ø Element to fix12
Tins - Torque (Nm)40
hef - Effective depth60
hnom - Min. anchor depth68
h1 - Drill hole depth min.75
d0 - Ø Drill10
hmin - Min. substrate thickness120
L - Lenght115
M10 x 135 Ø10
55
120
H
0
50
200
tfix - Max. fixture thickness55
SW - Installation key17
df - Ø Element to fix12
Tins - Torque (Nm)40
hef - Effective depth60
hnom - Min. anchor depth68
h1 - Drill hole depth min.75
d0 - Ø Drill10
hmin - Min. substrate thickness120
L - Lenght135
M10 x 165 Ø10
85
120
K
0
50
200
tfix - Max. fixture thickness85
SW - Installation key17
df - Ø Element to fix12
Tins - Torque (Nm)40
hef - Effective depth60
hnom - Min. anchor depth68
h1 - Drill hole depth min.75
d0 - Ø Drill10
hmin - Min. substrate thickness120
L - Lenght165
M10 x 185 Ø10
105
120
L
0
50
150
tfix - Max. fixture thickness105
SW - Installation key17
df - Ø Element to fix12
Tins - Torque (Nm)40
hef - Effective depth60
hnom - Min. anchor depth68
h1 - Drill hole depth min.75
d0 - Ø Drill10
hmin - Min. substrate thickness120
L - Lenght185
M12 x 80 Ø12
4
100
D
0
50
300
tfix - Max. fixture thickness4
SW - Installation key19
df - Ø Element to fix14
Tins - Torque (Nm)60
hef - Effective depth50
hnom - Min. anchor depth60
h1 - Drill hole depth min.65
d0 - Ø Drill12
hmin - Min. substrate thickness100
L - Lenght80
M12 x 100 Ø12
4
140
E
0
50
200
tfix - Max. fixture thickness4
SW - Installation key19
df - Ø Element to fix14
Tins - Torque (Nm)60
hef - Effective depth70
hnom - Min. anchor depth80
h1 - Drill hole depth min.85
d0 - Ø Drill12
hmin - Min. substrate thickness140
L - Lenght100
M12 x 110 Ø12
14
140
F
0
50
200
tfix - Max. fixture thickness14
SW - Installation key19
df - Ø Element to fix14
Tins - Torque (Nm)60
hef - Effective depth70
hnom - Min. anchor depth80
h1 - Drill hole depth min.85
d0 - Ø Drill12
hmin - Min. substrate thickness140
L - Lenght110
M12 x 120 Ø12
24
140
G
0
50
200
tfix - Max. fixture thickness24
SW - Installation key19
df - Ø Element to fix14
Tins - Torque (Nm)60
hef - Effective depth70
hnom - Min. anchor depth80
h1 - Drill hole depth min.85
d0 - Ø Drill12
hmin - Min. substrate thickness140
L - Lenght120
M12 x 130 Ø12
34
140
H
0
50
200
tfix - Max. fixture thickness34
SW - Installation key19
df - Ø Element to fix14
Tins - Torque (Nm)60
hef - Effective depth70
hnom - Min. anchor depth80
h1 - Drill hole depth min.85
d0 - Ø Drill12
hmin - Min. substrate thickness140
L - Lenght130
M12 x 150 Ø12
54
140
I
0
50
100
tfix - Max. fixture thickness54
SW - Installation key19
df - Ø Element to fix14
Tins - Torque (Nm)60
hef - Effective depth70
hnom - Min. anchor depth80
h1 - Drill hole depth min.85
d0 - Ø Drill12
hmin - Min. substrate thickness140
L - Lenght150
M12 x 180 Ø12
84
140
L
0
50
150
tfix - Max. fixture thickness84
SW - Installation key19
df - Ø Element to fix14
Tins - Torque (Nm)60
hef - Effective depth70
hnom - Min. anchor depth80
h1 - Drill hole depth min.85
d0 - Ø Drill12
hmin - Min. substrate thickness140
L - Lenght180
M12 x 200 Ø12
104
140
M
0
50
150
tfix - Max. fixture thickness104
SW - Installation key19
df - Ø Element to fix14
Tins - Torque (Nm)60
hef - Effective depth70
hnom - Min. anchor depth80
h1 - Drill hole depth min.85
d0 - Ø Drill12
hmin - Min. substrate thickness140
L - Lenght200
M16 x 145 Ø16
28
170
I
0
25
100
tfix - Max. fixture thickness28
SW - Installation key24
df - Ø Element to fix18
Tins - Torque (Nm)100
hef - Effective depth85
hnom - Min. anchor depth97
h1 - Drill hole depth min.105
d0 - Ø Drill16
hmin - Min. substrate thickness170
L - Lenght145
M16 x 175 Ø16
58
170
K
0
25
50
tfix - Max. fixture thickness58
SW - Installation key24
df - Ø Element to fix18
Tins - Torque (Nm)100
hef - Effective depth85
hnom - Min. anchor depth97
h1 - Drill hole depth min.105
d0 - Ø Drill16
hmin - Min. substrate thickness170
L - Lenght175
M16 x 220 Ø16
103
170
O
0
25
50
tfix - Max. fixture thickness103
SW - Installation key24
df - Ø Element to fix18
Tins - Torque (Nm)100
hef - Effective depth85
hnom - Min. anchor depth97
h1 - Drill hole depth min.105
d0 - Ø Drill16
hmin - Min. substrate thickness170
L - Lenght220
M16 x 250 Ø16
133
170
Q
0
25
50
tfix - Max. fixture thickness133
SW - Installation key24
df - Ø Element to fix18
Tins - Torque (Nm)100
hef - Effective depth85
hnom - Min. anchor depth97
h1 - Drill hole depth min.105
d0 - Ø Drill16
hmin - Min. substrate thickness170
L - Lenght250
M20 x 170 Ø20
32
200
K
0
20
40
tfix - Max. fixture thickness32
SW - Installation key30
df - Ø Element to fix22
Tins - Torque (Nm)200
hef - Effective depth100
hnom - Min. anchor depth114
h1 - Drill hole depth min.125
d0 - Ø Drill20
hmin - Min. substrate thickness200
L - Lenght170
M20 x 200 Ø20
62
200
N
0
20
40
tfix - Max. fixture thickness62
SW - Installation key30
df - Ø Element to fix22
Tins - Torque (Nm)200
hef - Effective depth100
hnom - Min. anchor depth114
h1 - Drill hole depth min.125
d0 - Ø Drill20
hmin - Min. substrate thickness200
L - Lenght200
M24 x 205 Ø24
35
250
N
0
10
30
tfix - Max. fixture thickness35
SW - Installation key36
df - Ø Element to fix26
Tins - Torque (Nm)250
hef - Effective depth125
hnom - Min. anchor depth143
h1 - Drill hole depth min.155
d0 - Ø Drill24
hmin - Min. substrate thickness250
L - Lenght205
M24 x 235 Ø24
65
250
P
0
10
20
tfix - Max. fixture thickness65
SW - Installation key36
df - Ø Element to fix26
Tins - Torque (Nm)250
hef - Effective depth125
hnom - Min. anchor depth143
h1 - Drill hole depth min.155
d0 - Ø Drill24
hmin - Min. substrate thickness250
L - Lenght235
[HIGH-LOAD ANCHOR] Male anchor for securing high-load elements in materials such as cracked and non-cracked concrete. It allows for the secure fastening of structural and non-structural elements with maximum reliability.
[CERTIFIED ANCHOR] Anchor bolt certified to the highest quality standards. It holds European approval ETA 12/0397 (Option 1), which certifies its performance in both cracked and uncracked concrete; it bears the CE mark; it has seismic approval C1 (for models M10 to M16) and C2 (for models M12 to M16); and it has fire resistance approval R30-R120.
[EASY INSTALLATION] Torque-controlled expansion anchor. It can be easily installed using a torque wrench. The clip design facilitates expansion. It features depth marks to ensure proper installation.
[HIGHLY VERSATILE ANCHOR BOLT] It can be used in the installation of structures such as overhead power lines, elevators, bridges, street furniture, and safety barriers, among others.
[GALVANIZED STEEL SHAFT AND STAINLESS STEEL CLIP] The anchor shaft is made of galvanized steel, and the clip is made of A4 stainless steel. These are highly durable materials that ensure the installation will last for years.
Nuestro departamento de ingeniería pone a tu disposición formaciones específicas y personalizadas en los diferentes temas relacionados con el mundo de la fijación: fijaciones metálicas o químicas, sistemas de instalación, normativas, realización de cálculos…
visitas a obra
La relación con nuestros clientes no finaliza con la venta de nuestros productos. Desde INDEX® entendemos que en muchas ocasiones es necesario un acompañamiento en obra donde nuestra experiencia es la mejor aliada para que todo encaje a la perfección. Nuestros ingenieros y técnicos apoyarán a los responsables de cada proyecto en la planificación y selección de la mejor solución con el fin de ahorrar tiempo y costes de la manera más efectiva.
SERVICIOS DE INGENIERÍA Y REALIZACIÓN DE CÁLCULOS
Desde INDEX® queremos ofrecer el servicio más integral a nuestros clientes. Además de proporcionarles las mejores soluciones en fijaciones y anclajes, nuestro equipo de ingenieros especializados, asesora técnicamente a todos nuestros clientes. Además, disponemos de potentes herramientas de software para realizar los cálculos necesarios con total exactitud.